In commercial construction, the terms "cold shell," "warm shell," and "fully fitted-out" refer to different levels of building completion, each with distinct cost and functionality implications. Here's a basic comparison of cold shell, warm shell, and full fit-out options in commercial construction projects in Australia:

Cold Shell Construction

Definition:

  • A basic building structure without interior finishes or services.
  • Typically includes the building envelope, structural elements, and basic utilities to the site boundary.

Advantages:

  • Lower initial cost for developers.
  • Greater flexibility for tenants to customise the space.
  • Shorter construction timeline for the developer.

Disadvantages:

  • Longer fit-out period for tenants.
  • Higher fit-out costs for tenants.
  • Requires tenants to manage additional construction work.

Typical Applications:

  • Warehouses and industrial spaces.
  • Retail spaces where tenants have specific fit-out requirements.

Warm Shell Construction and Fitout

Definition:

  • A building with basic interior finishes and services installed.
  • Includes HVAC, plumbing, electrical systems, and sometimes basic flooring and ceilings.

Advantages:

  • Quicker move-in time for tenants compared to cold shell.
  • Lower fit-out costs for tenants.
  • Basic infrastructure in place, reducing tenant coordination.

Disadvantages:

  • Higher initial cost for developers compared to cold shell.
  • Less flexibility for tenants compared to cold shell.
  • May require modifications to meet specific tenant needs.

Typical Applications:

  • Office spaces.
  • Retail spaces with standard fit-out requirements.

Full Building/ Tenancy Fit-Out

Definition:

  • A fully completed space ready for immediate occupancy.
  • Includes all interior finishes, fixtures, and fittings.

Advantages:

  • Quickest move-in time for tenants.
  • Predictable costs for tenants.
  • No additional construction work required for tenants.

Disadvantages:

  • Highest initial cost for developers.
  • Limited customization for tenants.
  • Longer construction timeline for developers.

Typical Applications:

  • Turnkey office spaces.
  • Retail spaces with standard design requirements.

Building Services Comparison

Cold Shell vs. Warm Shell Construction

Mechanical Services

Cold Shell Provisions:
  • Structural provisions only (plant spaces, risers, penetrations)
  • No active HVAC systems installed
  • Requires complete tenant HVAC installation
  • Must comply with AS 1668 for future ventilation systems
  • Typical cost impact: $350-450/m² for tenant installation
Warm Shell Provisions:
  • Central plant equipment installed
  • Main trunk lines and risers
  • Basic air distribution system
  • Building management system infrastructure
  • Requires tenant supplementary systems only
  • Typical cost impact: $150-250/m² for tenant customisation

Electrical Services

Cold Shell Provisions:
  • Main switchboard location only
  • Empty conduit paths and cable trays
  • Minimal temporary lighting
  • No power distribution
  • Must comply with AS/NZS 3000
  • Typical cost impact: $280-380/m² for tenant installation
Warm Shell Provisions:
  • Main switchboard installed
  • Base building power distribution
  • Basic lighting system
  • Emergency lighting
  • Distribution boards on each level
  • Requires tenant power and lighting customisation
  • Typical cost impact: $120-180/m² for tenant customisation

Plumbing Services

Cold Shell Provisions:
  • Core bathroom rough-in only
  • Main water supply points
  • Basic stormwater system
  • Compliant with AS/NZS 3500
  • No internal reticulation
  • Typical cost impact: $200-300/m² for tenant installation
Warm Shell Provisions:
  • Complete core bathrooms
  • Main water reticulation
  • Hot water system infrastructure
  • Basic tenant connection points
  • Requires tenant-specific additions only
  • Typical cost impact: $80-150/m² for tenant customisation

Fire Protection

Cold Shell Provisions:
  • Fire stairs and exits only
  • Main sprinkler infrastructure
  • Basic hydrant/hose reel system
  • Compliant with AS 2118 and AS 2419
  • No internal sprinkler reticulation
  • Typical cost impact: $180-250/m² for tenant installation
Warm Shell Provisions:
  • Complete sprinkler system
  • Fire detection and alarm system
  • Emergency warning system
  • Fire hydrants and hose reels
  • Requires minor tenant modifications only
  • Typical cost impact: $50-100/m² for tenant customisation

Communications

Cold Shell Provisions:
  • Main communications room space
  • Basic pathway infrastructure
  • No active systems
  • Must comply with AS/CA S009
  • Typical cost impact: $120-180/m² for tenant installation
Warm Shell Provisions:
  • Communications rooms fitted out
  • Vertical and horizontal pathways
  • Basic building systems only
  • Requires tenant-specific systems
  • Typical cost impact: $60-100/m² for tenant customisation

Building Management Systems

Cold Shell Provisions:
  • No BMS infrastructure
  • Provision for future installation only
  • Typical cost impact: $80-120/m² for tenant installation
Warm Shell Provisions:
  • Base building BMS installed
  • Core monitoring systems
  • Integration capability for tenant systems
  • Typical cost impact: $30-50/m² for tenant customization

Key Factors Influencing Choice

Cost:
  • Cold shell is the most cost-effective for developers but shifts costs to tenants.
  • Warm shell balances costs between developers and tenants.
  • Full fit-out is the most expensive for developers but offers cost certainty for tenants.
Project Timeline:
  • Cold shell offers the shortest timeline for developers.
  • Warm shell requires additional time for basic interior work.
  • Full fit-out has the longest timeline due to complete interior construction.
Tenant Requirements:
  • Cold shell is ideal for tenants with specific customization needs.
  • Warm shell suits tenants with moderate customization needs.
  • Full fit-out is best for tenants seeking immediate occupancy with minimal changes.
  • Relevant Australian Building Codes and Regulations

More on this topic: Download a comprehensive case study and detailed comparison of cold shell, warm shell and full fitout.

Please fill the required field.
Please fill the required field.

Please make sure that, re-captcha pluging is enabled

Image

Select a service to learn more

Planning & Development

Development Management

Early stage involvement designed to reduce client/ developer risk. Focus on budget, feasibility and constructibility.

Design & Documentation

Design Management

Collaborative, efficient coordination of design, documentation and specifications.

Project Management

Project Management

Professional management of construction projects. Focus on accountability, efficiency and risk mitigation.

Construction Services

General Contracting

Flexible project delivery models including construct only (GC), design & construct, construction management or cost-plus

Asset Management

Asset Protection

Asset management, planned and unplanned maintenance, abortive and remedial works, audits and inspections.

HSEQ Management

HSEQ Services

Health, Safety, Environment and Quality system management, auditing and risk analysis

Select your sector of interest to learn more

Aged Care

Aged Care

Aged Care construction and fitout

Childcare

Childcare & ELC

Turnkey Childcare planning, design and project management, construction, fitout and lifecycle maintenance.

Civil & Environmental

Civil & Environmental

Civil, infrastructure & environmental planning, design and project management, construction and lifecycle maintenance.

Commercial & Mixed-use

Commercial Construction

Commercial building project planning, design management, construction and lifecycle maintenance.

Community & Public

Public Spaces

Community centre & public venues planning, design and project management, construction, fitout and lifecycle maintenance.

Cultural & Worship

Cultural & Worship

Place of worship & cultural centre design and project management, construction, fitout and lifecycle maintenance.

Education & Training

Schools & Training Facilities

General & specialist training facility planning, design and project management, construction and lifecycle maintenance.

Hospitality & Restaurants

Hospitality & Restaurants

Restaurant building project planning, design management, construction, fitout, refurbishment and lifecycle maintenance.

Healthcare

Healthcare

Public & private healthcare facility planning, design and project management, construction, fitout and lifecycle maintenance.

General Practices

GP Clinics

Turnkey medical centre design and project management, construction, fitout and lifecycle maintenance.

Diagnostic Imaging

Radiology Centres

Radiology clinic, imaging department planning, design and project management, construction and lifecycle maintenance.

Labs & Cleanrooms

ISO & TGA Cleanrooms

Lab & sensitive environment project planning, design management, construction, fitout, refurbishment and lifecycle maintenance.

Industrial & Logistics

Manufacturing & Warehousing

Factories, industrial project planning, design and project management, construction, fitout and lifecycle maintenance.

Data Centre & Energy Storage

Data Centres, Energy Storage

Data centre, battery research and production design and project management, construction, fitout and lifecycle maintenance.

Retail & Shopping Centres

Retail & Shopping

Turnkey retail design and project management, construction, fitout and lifecycle maintenance.

Office Buildings

Office fitout

Office space project planning, design management, construction, fitout, refurbishment and lifecycle maintenance.